- Modbus rtu data logger serial#
- Modbus rtu data logger full#
- Modbus rtu data logger software#
- Modbus rtu data logger Pc#
- Modbus rtu data logger professional#
Modbus rtu data logger software#
The ethernet port can be used to connect to the BMS. Using the RS485 ports you can connect RS485 trunk/s with our converter and in each trunk, we can connect up to 31 devices using daisy chaining. Our Modbus RTU to BACnet IP converter cum data logger has 1 or 2 -RS485 ports (depending on model selected) and 1 Ethernet port.
Modbus rtu data logger professional#
Also, the customer and the site integrators have been extremely happy with the professional and timely services provided by the ProtoConvert team. This converter has been working on the site since long time now and have proven to be extremely efficient and reliable. ProtoConvert also helped the BMS team with questions and brining the Energy meter data into the BMS using our converter. Finally, ProtoConvert team submitted a complete site report and discovered all the Energy meter on BACnet IP using a 3 rd party BACnet discovery software.
Thus all the customer’s requirements were met. The reports for historical values can be downloaded or emailed. It is possible to generate reports using the web user interface. Additionally this model provides on board data logging and a simple web dashboard for monitoring values. With extremely minimal configuration (just a couple of clicks) it was possible to quickly integrate the Energy meters with the BMS. The ProtoConvert gateway made the integration almost plug and play. ProtoConvert analyzed the situation at hand and considering the two fold requirement of protocol conversion coupled with data logging recommend the ProtoConvert Modbus RTU data logger model PG-WS-100-103-DL.
Modbus rtu data logger Pc#
Data logging at the floor level so that reports can be generated at the floor and serve as data back up Our Modbus RTU Data-logging Software was designed for engineers, technical support personnel, and others who need an easy way to reliably gather, review, and log data from devices using the standard Modbus RTU protocol interface to a PC computer. Protocol conversion from Modbus to BACnet IP so that the BMS can monitor the energy meters Hence there should be local data logger per floor that keeps a logs data from the meters for local report generation. There is an additional requirement that the facility manager wants the ability to generate floor wise reports as a back up. The energy meters support Modbus RTU protocol but the BMS is o BACnet Ip protocol. To manage the premises, authority wants to monitor and analyze all the energy meters data like power, current, voltage etc. Hence the additional requirement of data logging and report generation per floor. Also the facility manager requires that data logs be kept per floor for energy and other readings on the meters. Hence the RS485 loops terminate on the floors and the data communication to the BMS is proposed to be over Ethernet. The BMS is installed on a server in the basement. The energy meters work on Modbus RTU on RS 485. Each floor has 2 RS485 loops of roughly 10 meters each. The building has 10 floors and 20 energy meters on each floor. At the same time they want a backup of data locally. One of a very well know building has 200 energy meters located on different floors and building management authority wants to get data of all the energy meters on central Building Management System (BMS).
Modbus rtu data logger serial#
Thanks to this option, you can timely resolve any problem that arises in your serial communication network. Once you start monitoring a required RS-485 interface, all data transmitted through it is shown in real time. The unique functionality of the app allows logging and filtering Modbus data communicated by specialized serial devices.Ĭonnecting to a COM port any time you need it even if the port is already used by another app.
Modbus rtu data logger full#
The software provides full support for Modbus RTU and Modbus ASCII protocols. The dedicated solution allows reading and recording Modbus data transferred over RS485/RS422/RS232 ports.
Core functionality of RS-485 Logger software